Ordering the wrong size of quadruplex wire is an expensive mistake. It can mean a rejected shipment, a delayed project, or a service drop that doesn’t suit the span it was bought for. Conductor size, neutral type and code-word naming all vary between suppliers, so a clear reference saves time.
This guide is for procurement managers, distributors, contractors and project buyers. It explains what quadruplex wire is, how it differs from triplex, and how to read a size chart from 6 AWG to 4/0 in AAC, AAAC and ACSR constructions. The reference data comes from the ASTM-standard aerial bundled cable range of HNBF Power (Henan Baofeng Cable Co., Ltd.), a cable manufacturer and supplier.
What Is Quadruplex Wire?
Quadruplex wire is a type of aerial bundled cable (ABC) used for overhead power distribution. It is also called quadruplex cable or quadruplex service drop cable. It is designed for three-phase supply, where one insulated cable replaces several separate overhead conductors.
Typical construction
- Phase conductors: Circular stranded, compacted aluminum conductors. The AAC, AAAC and ACSR options cover the covered line wire range, and the service drop sizes in this chart use AAC, AAAC or ACSR conductors.
- Insulation: Black polyethylene (PE) or cross-linked polyethylene (XLPE).
- Neutral: A bare AAC, AAAC or ACSR conductor that is bundled with the insulated phases.
The insulated phases lower the risk of short circuits and accidental contact compared with bare overhead conductors. They also resist weather, UV and oil, which matters for long outdoor service life.
Where it is used
Quadruplex wire suits overhead service applications such as residential power supply, construction sites, outdoor installations and street lighting networks. Utilities and electrical contractors also use it for service drop connections and overhead distribution lines. The rated voltage is 0.6/1 kV.
Quadruplex vs Triplex: Which One Do You Need?
The choice mainly depends on the supply system:
- Triplex is generally used where two insulated phase conductors are bundled with a neutral, such as single-phase service drops.
- Quadruplex adds a further insulated phase conductor, so it suits three-phase networks.
If your project mixes single-phase and three-phase connections, you may need both. HNBF Power’s ASTM range covers duplex, triplex and quadruplex service drop cable, as well as covered line wire, so one supplier can cover the mix.
Quadruplex Wire Size Chart (AAC, AAAC and ACSR)
The table below shows sample sizes from the HNBF Power quadruplex service drop range. Rated strength is in kg and weight is in kg/km, as listed in the manufacturer’s tables. Insulation thickness is in mm.
| Type | Code word | Phase size (AWG)–strands | Insulation (mm) | Neutral | Rated strength (kg) | Weight (kg/km) |
|---|---|---|---|---|---|---|
| AAC | Quarter | 6–1 | 1.143 | 6–7 | 256 | 211 |
| AAC | Mustang | 2–7 | 1.143 | 2–7 | 612 | 491 |
| AAC | Libyan | 1/0–7 | 1.524 | 1/0–7 | 903 | 790 |
| AAC | Oldenburg | 4/0–19 | 1.524 | 4/0–19 | 1,737 | 1,490 |
| AAAC | Bay | 6–1 | 1.143 | 6–7 | 503 | 217 |
| AAAC | Pony | 4/0–7 | 1.524 | 4/0–7 | 3,883 | 1,534 |
| ACSR | Morochuca | 6–1 | 1.143 | 6–6/1 | 540 | 229 |
| ACSR | Palomino | 2–7 | 1.143 | 2–6/1 | 1,293 | 557 |
| ACSR | Standardbred | 1/0–7 | 1.524 | 1/0–6/1 | 1,987 | 859 |
| ACSR | Appaloosa | 4/0–19 | 1.524 | 4/0–6/1 | 3,787 | 1,627 |
These are selected rows. The full range includes further sizes, such as 4 AWG, 2 AWG, 1 AWG, 2/0 and 3/0, in 7- and 19-strand versions. Always confirm values against the current datasheet before ordering.
AAC quadruplex
All-aluminum conductor is a common choice where cost-efficiency matters and spans are moderate. In the chart, the neutral matches the phase conductor size and strand count. See our AAC conductor page for the bare conductor details.
AAAC quadruplex
Aluminum alloy conductor generally gives higher strength than AAC at similar sizes. The chart reflects this: Bay (6 AWG, AAAC) lists a rated strength of 503 kg against 256 kg for Quarter (6 AWG, AAC). If you need more mechanical strength without a steel core, see our AAAC conductor range.
ACSR quadruplex
A steel-reinforced neutral adds tensile strength, which helps on longer spans or where mechanical loading is a concern. The 4/0 ACSR neutral in Appaloosa lists a rated strength of 3,787 kg, compared with 1,737 kg for the 4/0 AAC version. Learn more about ACSR conductor.
How to read the code words
Code words are standard names for each construction. In the quadruplex range they follow a horse theme, such as Quarter, Mustang, Shire, Libyan and Oldenburg for AAC. A code word identifies a specific combination of conductor size, stranding, insulation thickness and neutral. Quoting the code word along with the conductor type avoids confusion, because the same AWG size appears in several variants.
How to Choose the Right Quadruplex Wire Size
- Start with the load and system. Confirm that the network is three-phase and check the current each service must carry.
- Match the standard. Confirm the required standard (ASTM, IEC or NFC) before asking for prices. HNBF Power supplies ABC cable to ASTM, IEC and NFC standards.
- Pick the conductor material. AAC for economy, AAAC for added strength, ACSR where the neutral needs extra tensile strength.
- Check span and mechanical load. Compare the rated strength and weight columns against your installation conditions.
- Confirm the details that cause rejections. Core identification, insulation type and cable marking all matter (see below).
Technical Details Buyers Should Confirm
From the manufacturer’s specifications:
- Rated voltage: 0.6/1 kV
- Maximum service temperature: 90°C
- Maximum short-circuit temperature: 250°C (maximum 5 seconds)
- Minimum service temperature: −20°C
- Minimum bending radius: 15 × cable diameter
- Core identification: by color stripe, rib or number
- Cable marking: oil ink, laser or embossing
- Packaging: by roll, or on polywood, wooden or steel-wooden reels
Check these against your tender documents. Marking and packaging details are often overlooked, and they affect handling on site and delivery to remote locations.
What to Ask a Quadruplex Wire Manufacturer
A good supplier can make buying easier. Before placing a bulk order, ask:
- Can you supply the exact code word and conductor type I need?
- Which standard does the cable follow, and can you provide the relevant test documentation?
- What are the reel sizes, packaging options and typical lead time?
- Can the marking and core identification be customized?
Ask for documents rather than assuming. Reputable manufacturers are used to these questions.
Why Buyers Work With HNBF Power

Henan Baofeng Cable Co., Ltd. is a professional cable and wire manufacturer integrating R&D, production and sales. The factory was established in 2001 and is located in Gongyi City, Zhengzhou, Henan Province, China. HNBF Power supplies overhead insulated cable, bare conductors, concentric cable and power cable.
For importers, distributors and contractors, this means:
- One source for related products: ABC cable, AAC, AAAC and ACSR conductors under one roof.
- Standards flexibility: ABC cable available to ASTM, IEC and NFC standards.
- Responsive communication: Inquiries are answered within 24 hours, according to the company’s website.
If you already have a size list or tender specification, you can send us your requirements. Include the code word or AWG size, conductor type, quantity and destination, and the team can respond with specs and a quote.
FAQ
Q1. What is quadruplex wire used for?
Quadruplex wire is an aerial bundled cable used for overhead three-phase service drops and distribution lines, including residential supply, construction sites and street lighting networks.
Q2. What is the difference between quadruplex and triplex wire?
Triplex bundles two insulated phase conductors with a neutral and is typically used for single-phase supply. Quadruplex adds a further insulated phase and suits three-phase supply.
Q3. Which sizes of quadruplex wire are available?
The HNBF Power range covered in this chart runs from 6 AWG to 4/0, in AAC, AAAC and ACSR versions, with 1-, 7- and 19-strand constructions depending on size.
Q4. Should I choose an AAC, AAAC or ACSR neutral?
It depends on the span and mechanical load. AAC is economical, AAAC offers higher strength than AAC at similar sizes, and ACSR adds a steel core for extra tensile strength. Check the rated strength column for your size.
Q5. What voltage is quadruplex ABC cable rated for?
The HNBF Power ASTM range is rated 0.6/1 kV for AC networks, with up to 0.9 kV for DC networks according to local standards.
Q6. Can I request a custom size or marking?
Marking can be done by oil ink, laser or embossing printing, and core identification can be by color stripe, rib or number. Contact the team with your requirements to confirm what is available for your order.
Conclusion
Choosing quadruplex wire comes down to a few decisions: the right size, the right conductor material and the right standard. A clear size chart and code words make those decisions faster, and a manufacturer who can answer technical questions makes the order smoother.
Whether you are stocking a warehouse or specifying a utility project, HNBF Power can help you match the chart to your requirements. Request a quadruplex wire quote with your size, quantity and destination, and our team will reply with specifications and pricing.