subbanner

Quadruplex Cable Sizes & Code Names: ASTM AAC, AAAC, ACSR

You have a purchase order to fill, and the spec sheet says “Mustang 2-7” or “Pony 4/0-7.” If you don’t work with ASTM service drop cable every day, those names can look like a typo. They are the standard way to identify quadruplex cable, and once you know the system, specifying and comparing offers gets much faster.

This guide explains what quadruplex cable is, how the ASTM code names and sizes work, how the AAC, AAAC and ACSR options differ, and what to confirm before you order. It is written for procurement managers, distributors, contractors and project buyers. The technical data comes from the ASTM-standard product page of HNBF Power, a cable manufacturer and supplier based in Gongyi City, Henan, China.

What Is Quadruplex Cable?

quadruplex cable

Quadruplex cable is a type of aerial bundled cable (ABC) used for overhead service drops and distribution. It twists insulated aluminum phase conductors around a bare neutral so that the whole assembly hangs as a single, tidy bundle. It is sometimes called quadruplex wire or a quadruplex service drop.

In HNBF Power’s ASTM range, the phase conductors are circular, stranded, compacted aluminum, insulated with black polyethylene (PE) or cross-linked polyethylene (XLPE). The neutral is bare AAC, AAAC or ACSR. Typical applications include residential power supply, construction sites, outdoor installations and street lighting networks. The cable is designed for 0.6/1kV AC networks.

Compared with bare overhead conductors, insulated bundles lower the risk of short circuits and accidental contact. The insulation is also rated for weather, UV and oil resistance.

How Quadruplex Differs From Triplex and Duplex

The names describe how many conductors are in the bundle:

  • Duplex: one insulated phase conductor plus a neutral, for simple single-phase drops.
  • Triplex: two insulated phase conductors plus a neutral, common for single-phase service with a split-phase supply.
  • Quadruplex: three insulated phase conductors plus a neutral, used for three-phase service.

If you are sourcing for a three-phase load, quadruplex is the usual choice. Our ASTM aerial bundle cable page lists the duplex, triplex and quadruplex tables side by side, so you can compare them directly.

How ASTM Code Names Work

What “4/0-19” and “6-1” Mean

Each quadruplex entry pairs a code name with a size and stranding. The format is conductor size – number of wires:

  • 6-1 is a 6 AWG conductor with 1 wire.
  • 2-7 is a 2 AWG conductor with 7 wires.
  • 4/0-19 is a 4/0 AWG conductor with 19 wires.

Two items with the same AWG size can differ in stranding, which changes diameter and weight. Always confirm both numbers.

Why the Names Are Horses

In the ASTM code-word system, quadruplex cables are named after horse breeds. Examples from the AAC list include Quarter, Clydesdale, Pinto, Mustang, Shire, Libyan, Criollo, Orloff, Percheron, Mongolian, Hanoverian, Singlefoot and Oldenburg. Triplex cables use shellfish names and duplex cables use dog breeds. The convention gives buyers and utilities a short, unambiguous label for a cable, so a name such as “Mustang” carries a size, stranding and construction.

Choosing a Neutral: AAC, AAAC or ACSR

The code-name family tells you the neutral type, so this choice drives the item you order.

AAC (All Aluminum Conductor)

AAC is a good fit when the neutral does not need much extra strength and light weight matters. Its quadruplex names include Quarter, Mustang and Oldenburg.

AAAC (All Aluminum Alloy Conductor)

AAAC uses an aluminum alloy for higher rated strength at a comparable size. In the table, the 4/0-7 size has a rated strength of about 3,883 kg for the AAAC option (Pony), compared with about 1,737 kg for AAC (Singlefoot). Names include Bay, Arabian, Plow and Pony.

ACSR (Aluminum Conductor Steel Reinforced)

ACSR adds a steel core to the neutral for extra tensile strength. This suits longer spans or situations where mechanical load matters. Names include Morochuca, Palomino, Stallion and Appaloosa.

More on the neutral options is on our AAAC, ACSR and AAC product pages.

Sample Quadruplex Sizes at a Glance

The table below shows a few entries from our ASTM quadruplex service drop list, for orientation only. Values follow the product table and are nominal.

Code nameNeutral typePhase size-wiresInsulation (mm)Nominal diameter (mm)Rated strength (kg)Weight (kg/km)
QuarterAAC6-11.1434.115256.371211
MustangAAC2-71.1437.417612.347491
LibyanAAC1/0-71.5249.347902.644790
SinglefootAAC4/0-71.52413.2591,737.2501,485
BayAAAC6-11.1434.115503.485217
PonyAAAC4/0-71.52413.2593,882.7301,534
MorochucaACSR6-11.1434.115539.772229
StallionACSR4/0-71.52413.2593,787.4771,622

Please use the full tables on the product page, or ask us for the current datasheet, before finalizing a purchase.

Key Specifications Buyers Should Confirm

Before you send a request for quotation, check these items against your project spec:

  • Voltage: the ASTM range is rated 0.6/1kV.
  • Temperature performance: a maximum service temperature of 90°C, a short-circuit temperature of 250°C (maximum 5 seconds) and a minimum service temperature of -20°C.
  • Insulation: black PE or XLPE.
  • Core configuration: the range includes 1, 1+1, 2+1 and 3+1 constructions. Quadruplex corresponds to 3+1.
  • Core identification: by color stripe, rib or number.
  • Minimum bending radius: 15 times the cable diameter, which matters for reel handling and installation planning.
  • Installation conditions: open air or buried, per the specification.
  • Marking and packaging: oil ink, laser or embossing printing, and packing by roll or in polywood, wooden or steel-wooden reels.

Ampacity, sag and span limits depend on your local code and network design. Treat the catalog table as a starting point and have your engineer confirm the final size.

Common Ordering Mistakes

  1. Confusing triplex and quadruplex names. Shellfish names are triplex and horse names are quadruplex. Ordering from the wrong list gives you the wrong bundle.
  2. Ignoring stranding. A “2-7” and a “2-1” are not interchangeable in diameter or flexibility.
  3. Picking a neutral by price alone. An AAC neutral may be cheaper, but if your spans need more strength, AAAC or ACSR may be the better value.
  4. Skipping reel and length planning. Confirm the reel type, cable length and packaging before shipping, especially for export.
  5. Not stating the standard. ASTM, IEC and NFC constructions differ. State the standard clearly in your order. HNBF Power also makes ABC cable to IEC and NFC standards.

Working With HNBF Power as Your Manufacturer & Supplier

quadruplex cable

Henan Baofeng Cable Co., Ltd. (HNBF Power) is a professional cable and wire manufacturer that combines R&D, production and sales. The factory was established in 2001 and sits in the Science & Technology Industrial Park in Gongyi City, Zhengzhou, Henan Province, China. Beyond quadruplex cable, the range includes bare conductors, other overhead insulated cables, concentric cable, power cable, control cable and more.

For quadruplex buyers, that means a direct line to a manufacturer that can quote on the size, neutral type, marking and packaging details covered above. Whether you are a distributor stocking common sizes or a project buyer with a fixed bill of quantities, you can send the code name, quantity and destination and get a clear reply. The website states that inquiries are answered within 24 hours.

Ready to compare options? Request a quadruplex cable quote with your size, neutral type and quantity, and we’ll help you match it to the right ASTM item.

Frequently Asked Questions

Q1. What is quadruplex cable used for?
It is used for overhead service drops and distribution lines, typically for three-phase supply, including residential power, construction sites, outdoor installations and street lighting.

Q2. What is the difference between triplex and quadruplex cable?
Triplex has two insulated phase conductors plus a neutral. Quadruplex has three insulated phase conductors plus a neutral, which makes it suitable for three-phase service.

Q3. Why do ASTM quadruplex cables have horse names?
The ASTM code-word system gives each construction a standard name so buyers and utilities can identify it quickly. Quadruplex entries use horse breeds such as Mustang, Percheron and Pony.

Q4. Should I choose an AAC, AAAC or ACSR neutral?
It depends on the mechanical load. AAC is light, AAAC offers higher strength for similar sizes, and ACSR adds a steel core for extra tensile strength. Your span length and design requirements should guide the final choice.

Q5. Can I request a specific marking or packaging?
HNBF Power lists oil ink, laser and embossing printing for cable marking, and roll or reel packaging in polywood, wooden or steel-wooden options. Confirm your preferences when you request a quote.

Conclusion

Quadruplex cable looks complicated mainly because of the naming. Once you know that the code name identifies the neutral family, and the size and wire count tell you the phase conductor, an ASTM spec sheet becomes easy to read. Check the voltage, temperature, insulation, core identification and packaging details, and match the neutral type to your mechanical needs.

If you would like a second pair of eyes on a specification or a price for a specific size, contact HNBF Power with your code name, quantity and destination, and our team will help you move from datasheet to delivery.

Scroll to Top